Facebook
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier

10way RDM&DMX Splitter Distributor DMX Signal Amplifier

Ten-output RDM and DMX splitter and signal amplifier: one console feed to ten clean, labelled outputs for large rigs.
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier
  • 10way RDM&DMX Splitter Distributor DMX Signal Amplifier

Description

Product Overview

A ten-way RDM and DMX splitter takes the single data feed coming from your dmx lighting controller and sends it out again from ten separate outputs. Instead of one long daisy chain limping across the stage, each truss position, flown bar and downstage run gets its own home run back to a single rack unit. The signal is re-driven on the way out, so every output reaches its first fixture at full strength rather than as the tail end of a chain that has already passed through thirty heads.

It belongs where the data stops being simple: dimmer city, a front-of-house position, or a stage-side rack feeding several directions at once. One input, ten outputs, and a front face you can re-patch during a changeover without sliding the unit out of the rack.

Because RDM is carried as well as DMX, the return path stays open. Fixture status, addressing and sensor readings from the far end of a run travel back through the splitter to the desk, which is what keeps a dmx lighting system manageable once the rig is too big to walk with a tester in your hand.

Physically it is a metal chassis with rack ears, XLR connectors on the front and the mains inlet at the rear — the kind of box that lives in a rack and is forgotten about until someone kicks a cable out. Ten outputs also means fewer units in the rack, so a rig that would otherwise need two smaller splitters fits into one.

Rack & Connector Layout

The chassis is metal with a matte black finish and rack ears on both sides, so the unit screws into a rack drawer, a dimmer-city rack or a road case and then stays there. Front-mounted connectors keep the patching face reachable with the unit bolted in — you re-patch from the front instead of pulling the box forward to reach the back.

The outputs are grouped and labelled across the front panel, which matters more than it sounds. At three in the morning during a changeover, a labelled row tells a stagehand which line goes to the fly floor without tracing a cable through a bundle.

The power switch is on the front panel with ON and OFF marked, so a unit can be isolated without pulling the mains lead out of the back. At the rear sit the IEC inlet and the fuse holder; keep a spare fuse of the correct rating in the rack, because a blown fuse is the failure that stops a splitter dead while everything around it still works.

Every connection is a standard XLR, so the splitter speaks the same connector language as the rest of the rig — the dmx controller for moving heads at front of house, the wall panels and the fixtures all patch with the cable you already carry, and an emergency re-patch needs no adaptor.

In a touring rack, group the splitter with the power distribution rather than with the fixture spares. It wants short mains and short data tails, and putting it beside the distro keeps both runs tidy and out of the walkway.

Installation & Wiring

  1. Rack the splitter where the cable runs converge — dimmer city, a stage-left rack or the front-of-house position — so no output needs an extension to reach its first fixture. If the rack itself is flown, secure the unit on its rack ears and never let it hang on its own cables.
  2. Bring the console line into the input and check it before connecting anything downstream. A splitter will faithfully re-send a bad signal from the desk, so a fault found here saves an hour of searching the rig.
  3. Feed the unit from your dmx 512 controller with a short, good-quality cable, and keep that first link out of the path where flight cases get dragged.
  4. Run one output per direction as a home run, and resist the temptation to chain two directions together just because the next output along is free.
  5. Terminate the last fixture on each run as you would on any DMX line, keep the total load on each line inside what a single line is designed to carry, and split again with a second output rather than pushing a run to its limit.
  6. Label both ends of every cable against its output number before the rig goes up. That label is what saves the show when a connector is pulled out mid-set.
  7. Power up, confirm the front switch is on, then check that fixtures respond on every output and that RDM discovery finds them from the desk.

Output Capacity & Rig Planning

  • Count directions, not fixtures. Each output is a separate line, so ten truss positions, ten winch bars or ten rooms can each be fed from the same dmx lighting controller output without chaining one into the next.
  • Ten outputs is the size for the moment a rig outgrows a simple split — when stage right, the fly floor and the follow-spot position all want their own line, splitting again is not an option and doubling up is the wrong answer.
  • Keep one or two outputs free. A spare line covers a late-added fixture position, a floor package or a guest console without re-patching the whole rack an hour before doors.
  • One output per direction keeps faults small. If a cable is crushed under a flight case, a single truss goes quiet instead of the entire rig, and the fault is isolated to one numbered output rather than somewhere along a fifty-metre chain.
  • It handles mixed rigs comfortably: the dmx controller for moving heads on the tour and the static LED fixtures on the same stage can sit on separate outputs, so re-patching a moving-head run never disturbs the washes.
  • For a rental house, ten outputs often means one prep bench instead of two — the whole dmx led stage lighting stock for a mid-size tour can be addressed, tested and labelled through a single splitter before it leaves the warehouse.
  • If you are between sizes, take the larger unit. Extra outputs cost rack space once; a shortage of ports costs you a re-patch at every load-in for the life of the rig.

Applications

  • Touring and festival stages — the unit sits in the dimmer rack and feeds each truss as an independent run, so a cable destroyed by a flight case at stage right never takes out the overhead rig.
  • Theatres and multi-space venues — a rep plot covering a main house, a studio and a foyer can be fed from one dmx lighting system splitter, with each space on its own output so the studio can be re-patched while the main house runs.
  • Television and broadcast studios — where every grid position is a separate home run and the dmx 512 controller stays at the gallery position, the splitter is the quiet point in the middle that nobody has to touch during a record.
  • Rental house prep benches — before a dmx led stage lighting order ships, the whole consignment can be addressed, tested and labelled from one bench through a single splitter instead of a temporary pile of adaptors.
  • Clubs and venues spread over several rooms — bar, dance floor and terrace each keep their own output, so a fault in one area stays a local problem instead of a dark building.
  • Outdoor events — the splitter stays in a protected rack while the long runs go out to the stage, so the electronics are never the part left standing in the rain.
  • Permanent installations — a single rack position feeds the different directions of a fixed rig, and the front-panel labels are what a visiting technician works from when the person who built the system has moved on.

Specifications

PropertyDetail
Outputs10
Input1 DMX input
Signal functionDistribution and re-amplification of the incoming DMX feed
ProtocolDMX512
RDMSupported
Output connectorsXLR
Connector type3-pin or 5-pin XLR, confirmed against your order
ChassisMetal, matte black finish
MountingRack ears for fixed rack installation
Front panelPower switch and labelled outputs
Power inletIEC inlet with fuse holder at the rear
Typical useData distribution on entertainment and stage rigs

Ordering & Delivery

  1. Confirm the output count against the rig you are building. Ten outputs suits a rig with several truss positions or a rack feeding more than one space; if your patch is smaller, say so and we will recommend the version that fits instead of selling you spare ports. It is a simple decision now and an expensive one once the rack has been wired.
  2. Confirm whether the dmx controller for moving heads on your rig will feed them from shared outputs or from dedicated runs, since that changes how the outputs are allocated.
  3. Ask for the current minimum order quantity and any price breaks at higher volumes; both depend on the order and are quoted per project. Give us the show or installation date so lead time can be checked against it before you commit, and we will confirm the production and delivery schedule with you. Agree payment terms and Incoterms with your sales contact when the order is placed, and confirm the packing that suits your freight method. Warranty cover, the scope of that cover, and the procedure for a unit that arrives damaged or develops a fault are set out in writing at order stage — as a dmx lighting controller supplier we would rather agree that up front than debate it after the truck has left.
  4. Shipping is quoted per destination. As a dmx lighting controller manufacturer we ship from Guangzhou and pack for air or sea freight according to the schedule you are working to.
  5. DocumentWhat it covers
    Specification sheetOutput count, connector type, power inlet and physical data for the unit
    User manualRack mounting, wiring sequence and front-panel operation
    DMX and RDM referenceChannel and parameter information for addressing and programming
    Photometric dataOutput data for lighting design work where the project requires it
    DrawingsOutline and panel drawings for rack planning and rig documentation
    Compliance paperworkDocumentation relevant to your destination market
    AvailabilityAsk your sales contact which files are ready for your project and in which format

Technical Support & Model Matching

More than 30 engineers with an average of 15+ years in professional lighting stand behind every order — the same people who answer your technical questions. Tell us your venue, rigging height, throw distance and existing control setup; we help match models, check protocol and channel fit, and build a package that works as one system. If a fixture misbehaves on site, we work through the fault with you and sort out spares. Installation and commissioning guidance come with the order. Founded in 2016, exporting since 2022, LITEVISION serves buyers in more than 80 countries from offices in the USA, Taiwan, Mexico and China.

FAQ

Does RDM still work after the signal passes through the splitter?

Yes. RDM replies from fixtures on any output travel back up the line to the desk, so the dmx lighting controller at front of house can read sensor values, check addressing and identify a fixture without sending anyone up a truss with a tester. Discovery behaves the way it does on a direct line — the practical difference is that the replies arrive from whichever numbered run the fixture sits on, which makes a fault quicker to locate.

How many fixtures can I put on a single output?

A splitter does not change the load rules of a DMX line — each output is still one line, so keep every run inside what one line is designed to carry and terminate the last fixture on it. If a truss needs more than that, take a second output to it rather than chaining further. That is the advantage of ten outputs: your dmx 512 controller sees ten short, healthy lines instead of one long one, and splitting again is cheaper than pushing a line to its limit.

Should the splitter sit at front of house or at the stage?

Whichever position shortens the cable runs. In most dmx lighting system designs the unit sits at dimmer city or in a stage-side rack, because that is where the directions fan out towards the trusses. Front of house is the better choice when the console position is also where the rig divides, or when you want to keep the split off the stage floor where it can be kicked.

Are cables and adaptors included with the unit?

The unit arrives with its XLR panel connectors fitted; cables, adaptors and rack hardware are separate items. Tell us what your rack already uses and the connector type on your order will be matched to it. Because we work as a dmx lighting controller supplier for rental and install customers, we would rather settle the connector question at the quotation stage than have you re-terminate a rack on site.

Will it work with fixtures from other brands?

It distributes a DMX512 signal, so any fixture that speaks DMX512 can sit on an output regardless of who made it, provided the connector type matches. That makes the unit useful in mixed inventories where an older wash package and a newer moving-head fleet share a rig. We build it as a dmx lighting controller manufacturer working with our own fixtures every day, but the protocol is the protocol — the thing worth checking is the pin-out on the connectors your other fixtures use.

Is there a smaller version if ten outputs is more than I need?

Yes — as a dmx lighting controller manufacturer we build the same splitter family with six outputs as well, which suits a single-truss rig or a compact venue. Choose ten when the rig has several directions, when more than one space is fed from one rack, or when you want spare lines for guest consoles and floor packages. For a dmx led stage lighting installation that is expected to grow, the ten-output unit usually saves buying a second splitter later.

Download