A Compact Six-Way Hub for the Point Where the Rig Divides
The 6-way RDM DMX splitter is built for the moment a rig stops being one clean line. It accepts a single DMX512-RDM feed and repeats it across six isolated outputs, each with its own power supply and protection circuit, so a damaged run at one truss position does not pull the rest of the show down with it.
As a DMX signal amplifier, it sits where the console feed has to become several branches: front of house, a dimmer position, a stage-side rack or the first upstage truss. Six outputs cover a mid-size rig with two truss positions, a stage side, a dimmer run and a spare branch, without turning the data case into a rack.
The housing is compact enough to sit at the split point rather than back at the console, and it works with any DMX512 fixture and any RDM-capable controller; the connector pin convention is the part to match before the order is fixed.
How a Fault Stays on One Branch
- Independent power per input and output. Each port has its own supply, so a fault on one run is not fed from the same rail as the other five.
- Photoelectric isolation on every board. Independent protection circuitry and photoelectric isolation keep the data side electrically separated from the power side.
- Protection at the port that takes the hit. Current pushed back down a stage cable meets that output's own protection circuit before it can travel toward the controller.
- The other five outputs keep passing DMX. A damaged downstream cable becomes a local problem rather than a blackout across the rig.
- Field replacement without pulling the unit. If a strong current from the stage side takes out an output module, that module can be replaced on site and the splitter put back into service.
- Small enough to live at the damage point. It can be mounted close to the truss or dimmer position, where cables are most exposed.
Swappable XLR-3 and XLR-5 Ports
The input and each of the six outputs are separate modules, built as 3-pin XLR (XLR-3) or 5-pin XLR (XLR-5) assemblies. The mix is chosen port by port, so a 5-pin console feed can sit beside 3-pin runs to older fixtures without an adaptor chain.
Silver-metal XLR connectors take repeated mating, and a single port can be changed to the other pin standard without replacing the whole unit. That helps when a tour picks up local cable in a territory working on the other convention, or when a venue's house wiring has to be accommodated at short notice.
If a module is damaged, the unit does not have to leave the rig. The input and output modules are replaceable at the split point, which is the difference between losing one branch for a few minutes and losing the whole split until a spare arrives.
RDM Feedback Through Six Branches
- Two-way DMX512-RDM. Commands travel down each branch and replies come back up; the splitter passes both directions.
- Fixture data at the desk. The unit can feed light data back to an MA or another RDM-capable controller, so the desk can see what is answering on each branch.
- Addressing before doors. Discovery and address changes can be made from the controller instead of walking to every truss position.
- Fault finding without a ladder. When a fixture stops answering, RDM can show which branch it sits on before anyone climbs.
- Non-RDM fixtures still work. Older units receive their DMX normally; they simply do not reply, so they will not appear in the controller's device list.
- Check the whole chain in pre-production. RDM has to be enabled and understood by the desk and by the fixtures as well as by the splitter.
Technical Data
| Property | Detail |
|---|
| Input | 1 × DMX512-RDM input |
| Outputs | 6 × isolated outputs |
| Protocol | DMX512-RDM, bidirectional |
| RDM | Fixture data returned to an RDM-capable controller |
| Input/output modules | Swappable 3-pin XLR (XLR-3) or 5-pin XLR (XLR-5), chosen per port |
| Isolation | Independent protection circuit and photoelectric isolation per module |
| Power | Independent power supply for each input and output |
| Connectors | Silver-metal XLR |
| Field service | Input and output modules replaceable on site |
| Net weight | 0.86 kg |
| Dimensions | 11.5 × 17 cm |
Wiring the Six Branches
- Place the splitter where the DMX line divides — front of house, a dimmer position or the first truss — and fix it independently so the cables are not carrying its weight.
- Bring the incoming line from the controller or the last node into the input module, and check that the cable pin convention matches the module fitted.
- Choose the output modules: 3-pin and 5-pin can be mixed port by port, so each run leaves on the connector its far end expects.
- Run one output to one destination. Six branches should mean six separate runs, not six cables that rejoin further down.
- Connect power only after the data cabling is in place, and keep the mains and data tails short and out of the walkway.
- Test each output with a few fixtures before the full truss is connected, and label the output at the panel as you confirm the run it feeds.
- Terminate the last fixture on each branch and keep the run within the load a single DMX line is designed to carry; if a truss needs more, take a second output rather than chaining further.
- On mixed inventories, leave non-RDM fixtures on their own branch if you want a clean device list at the desk.
Order Details, Files and Compliance
| Item | What is confirmed |
|---|
| Minimum order quantity | Quoted for the quantity and module mix you need; no fixed figure is published. |
| Batch pricing | Confirmed with the order; the split between 3-pin and 5-pin modules is part of the quotation. |
| Production lead time | Checked against your show or installation date before the order is released. |
| Payment and trade terms | Agreed with your sales contact when the order is placed. |
| Warranty | Length and scope are confirmed in writing with the order. |
| Returns and quality claims | Report transit damage or a fault with the output number and photos; the handling process is confirmed with the order. |
| Datasheet and user manual | Issued with the unit; cover connector options, weight, dimensions, module fitting and output checks. |
| Wiring and RDM reference | XLR-3 and XLR-5 pin assignment, plus notes on RDM feedback to the controller. |
| DMX channel table | Not applicable; the splitter does not occupy DMX channels. |
| Photometric data | Not applicable; the unit produces no light output. |
| Compliance documents | Region-specific; tell us the destination market and we confirm which paperwork applies before shipment. |
| Companion equipment | Any DMX512 fixture and RDM-capable controller; the connector pin convention is the item to match. |
Engineering Support After the Split Point
They can talk through pin conventions, RDM behaviour and module mix before the order is fixed, and stay with the problem if a unit misbehaves on site. Founded in 2016 and exporting since 2022, LITEVISION supports buyers in more than 80 countries from offices in the USA, Taiwan, Mexico and China. Installation and commissioning guidance come with the order; if a module is damaged, the aim is to get that branch back in service rather than leave a rental house with a dead output.
Technical Support & Model Matching
More than 30 engineers with an average of 15+ years in professional lighting stand behind every order — the same people who answer your technical questions. Tell us your venue, rigging height, throw distance and existing control setup; we help match models, check protocol and channel fit, and build a package that works as one system. If a fixture misbehaves on site, we work through the fault with you and sort out spares. Installation and commissioning guidance come with the order. Founded in 2016, exporting since 2022, LITEVISION serves buyers in more than 80 countries from offices in the USA, Taiwan, Mexico and China.
FAQ
What happens to the other outputs if one branch is damaged?
The other five outputs keep passing DMX. Each input and output has its own independent power supply and its own protection circuit with photoelectric isolation, so current pushed back down one stage cable meets that branch's protection rather than the shared electronics. If the output module itself is taken out, it can be replaced on site.
Can I mix 3-pin XLR and 5-pin XLR on the same unit?
Yes. The input and each of the six outputs are separate swappable modules, so a 5-pin input can sit next to 3-pin outputs, or the other way round. Decide the mix per port before the order is released, and keep one spare module of the other type in the data case if the rig travels.
Is this a DMX signal amplifier as well as a splitter?
It is both. One DMX512-RDM input is distributed to six isolated outputs, and the data passes through unchanged apart from electrical separation. The signal amplifier name refers to its role in carrying the line across six branches; it does not alter DMX values.
Will RDM still reach the console through all six outputs?
Yes. DMX512-RDM is bidirectional here, and the splitter can feed light data back to an MA or another RDM-capable controller. Fixtures that do not support RDM still receive DMX normally; they simply do not reply, so they will not appear in the controller's device list.
Where do I set addresses — on the splitter or at the console?
Addressing belongs at the console and at the fixtures; the splitter is deliberately passive on that front. A DMX512-RDM address is a property of the receiving device, so the start address for each fixture, dimmer or moving head is set on that unit itself, either from its own menu or over RDM from the desk, and the splitter simply carries the conversation between the two.
In practice that means the rig can be addressed before or after it is divided. Build the patch in the console, run discovery down each branch, and confirm that every responder reports the address you expect. Setting addresses from the desk is no different on a branch than on a straight run, so the console remains the single place where the show is patched.
No address data lives in the splitter, which is worth knowing on a busy day. Changing a port to the other pin convention, or dropping in a spare unit, leaves the patch exactly as it was, and every fixture keeps the address it was last given. The patch sheet in the console stays the master record; the hardware at the split point is just the road between desk and fixture.
Two habits keep the split point tidy. Label each branch against the patch so a fault can be traced to the right truss position without pulling cable. After any re-patch, run discovery branch by branch rather than trusting one whole-rig scan, because a silent branch is then clearly a cabling or power question rather than an addressing one. If a fixture answers but refuses a new address over RDM, check that fixture's own RDM setting is enabled before suspecting the splitter.
How should the unit be fixed at the split point?
Fix the housing independently at the truss, rack or dimmer position where the line divides, and support the cables on both sides so the connectors are not carrying the weight. Keep the mains and data tails short and out of the walkway.